Technical - TIRRON GmbH http://tirron.com/index.php/services/technical Thu, 26 Jun 2025 11:33:26 +0000 Joomla! - Open Source Content Management en-gb Technical Services http://tirron.com/index.php/services/technical/4-technical-services http://tirron.com/index.php/services/technical/4-technical-services
  • CS&S and maintenance
  • system integration
  • calibration service, temperature, pressure, mass flow
  • commissioning, onsite and pre-installation
  • hardware modifications
  • control system upgrade
  • CE certification
  • CE

    ]]>
    cschuetz@tirron.com (Super User) Tue, 22 May 2012 14:15:04 +0000
    Load Upgrade http://tirron.com/index.php/services/technical/34-load-upgrade http://tirron.com/index.php/services/technical/34-load-upgrade Included in our load upgardes are properly sized flexible load cables and protection fuses, if required.

    Loads will be integrated in the test station control software, including automated test scripting, alarm handling, data logging and graphing.

    ]]>
    cschuetz@tirron.com (Super User) Mon, 03 Mar 2025 08:18:32 +0000
    GI-DAQ Replacement http://tirron.com/index.php/services/technical/35-gi-daq-replacement http://tirron.com/index.php/services/technical/35-gi-daq-replacement Replacement of GI-DAQ system with Beckhoff IO to increase reliabillity

    ]]>
    cschuetz@tirron.com (Super User) Mon, 03 Mar 2025 08:34:47 +0000
    MFC Calibration http://tirron.com/index.php/services/technical/26-mfc-calibration http://tirron.com/index.php/services/technical/26-mfc-calibration We offer onsite MFC calibration of Alicat and Bronkhorst MFC from 20nmlpm - 8000 nlpm flow range.

    MFCCal

    MFCs will be calibrated in their installed
    position. MFCs will be calibrated with
    customer gas infrastructure, including its
    limitations. Available for H2, N2, O2, Air and
    CO2 (O2 and CO2 with Bronkhorst
    correction factors). With TIRRON
    calibration certificates. Does not include repair of MFCs, which cannot be calibrated.
    (MFC can not be calibrated within our tolerances) TIRRON Reference is
    calibrated at ISO 17025 certified laboratory with 1 year calibration interval. With 5
    calibration points: 0, 20, 40, 60, 80 and 100
    % FS. Available ranges 20 nmlpm - 8000
    nlpm.
    Tolerance and Uncertainty:
    20nmlpm - 1000 nlpm:
    -Tolerance: 1 % Measurement + 0.2 % Full
    Scale of DUT
    -Uncertainty: 0.5 % Measurement + 0.1%
    Full Scale of used References

    ]]>
    cschuetz@tirron.com (Super User) Thu, 08 May 2014 11:13:48 +0000