Technical - TIRRON GmbH http://tirron.com/index.php/services/technical 2025-06-26T10:37:26+00:00 Joomla! - Open Source Content Management Technical Services 2012-05-22T14:15:04+00:00 2012-05-22T14:15:04+00:00 http://tirron.com/index.php/services/technical/4-technical-services Super User cschuetz@tirron.com <ul> <li>CS&amp;S and maintenance</li> <li>system integration</li> <li>calibration service, temperature, pressure, mass flow</li> <li>commissioning, onsite and pre-installation</li> <li>hardware modifications</li> <li>control system upgrade</li> <li>CE certification</li> </ul> <p><img src="images/2025/ce.png" border="0" alt="CE" width="500" /></p> <ul> <li>CS&amp;S and maintenance</li> <li>system integration</li> <li>calibration service, temperature, pressure, mass flow</li> <li>commissioning, onsite and pre-installation</li> <li>hardware modifications</li> <li>control system upgrade</li> <li>CE certification</li> </ul> <p><img src="images/2025/ce.png" border="0" alt="CE" width="500" /></p> Load Upgrade 2025-03-03T08:18:32+00:00 2025-03-03T08:18:32+00:00 http://tirron.com/index.php/services/technical/34-load-upgrade Super User cschuetz@tirron.com <p>Included in our load upgardes are properly sized flexible load cables and protection fuses, if require<span style="font-size: 12.16px;">d.</span></p> <p><span style="font-size: 12.16px;"><img src="images/2025/busbar.jpg" border="0" alt="" /></span></p> <p><span style="font-size: 12.16px;"><span style="font-size: 12.16px;">Loads will be integrated in the test station control software, including automated test scripting, alarm handling, data logging and graphing.</span></span></p> <p>Included in our load upgardes are properly sized flexible load cables and protection fuses, if require<span style="font-size: 12.16px;">d.</span></p> <p><span style="font-size: 12.16px;"><img src="images/2025/busbar.jpg" border="0" alt="" /></span></p> <p><span style="font-size: 12.16px;"><span style="font-size: 12.16px;">Loads will be integrated in the test station control software, including automated test scripting, alarm handling, data logging and graphing.</span></span></p> GI-DAQ Replacement 2025-03-03T08:34:47+00:00 2025-03-03T08:34:47+00:00 http://tirron.com/index.php/services/technical/35-gi-daq-replacement Super User cschuetz@tirron.com <p><span>Replacement of GI-DAQ system with Beckhoff IO to increase reliabillity</span></p> <p><img src="images/2025/gi-daq.jpg" border="0" alt="" /></p> <p><span>Replacement of GI-DAQ system with Beckhoff IO to increase reliabillity</span></p> <p><img src="images/2025/gi-daq.jpg" border="0" alt="" /></p> MFC Calibration 2014-05-08T11:13:48+00:00 2014-05-08T11:13:48+00:00 http://tirron.com/index.php/services/technical/26-mfc-calibration Super User cschuetz@tirron.com <p><span style="font-size: 12.16px;">We offer onsite MFC calibration of Alicat and Bronkhorst MFC from 20nmlpm - 8000 nlpm flow range.</span></p> <p><span style="font-size: 12.16px;"><img src="images/2025/calsuitcase2.jpg" border="0" alt="MFCCal" width="700" style="vertical-align: middle;" /></span></p> <p>MFCs will be calibrated in their installed<br />position. MFCs will be calibrated with<br />customer gas infrastructure, including its<br />limitations. Available for H2, N2, O2, Air and<br />CO2 (O2 and CO2 with Bronkhorst<br />correction factors). With TIRRON<br />calibration certificates. Does not include repair of MFCs, which cannot be calibrated.<br />(MFC can not be calibrated within our tolerances) TIRRON Reference is<br />calibrated at ISO 17025 certified laboratory with 1 year calibration interval. With 5<br />calibration points: 0, 20, 40, 60, 80 and 100<br />% FS. Available ranges 20 nmlpm - 8000<br />nlpm.<br />Tolerance and Uncertainty:<br />20nmlpm - 1000 nlpm:<br />-Tolerance: 1 % Measurement + 0.2 % Full<br />Scale of DUT<br />-Uncertainty: 0.5 % Measurement + 0.1%<br />Full Scale of used References</p> <p><span style="font-size: 12.16px;">We offer onsite MFC calibration of Alicat and Bronkhorst MFC from 20nmlpm - 8000 nlpm flow range.</span></p> <p><span style="font-size: 12.16px;"><img src="images/2025/calsuitcase2.jpg" border="0" alt="MFCCal" width="700" style="vertical-align: middle;" /></span></p> <p>MFCs will be calibrated in their installed<br />position. MFCs will be calibrated with<br />customer gas infrastructure, including its<br />limitations. Available for H2, N2, O2, Air and<br />CO2 (O2 and CO2 with Bronkhorst<br />correction factors). With TIRRON<br />calibration certificates. Does not include repair of MFCs, which cannot be calibrated.<br />(MFC can not be calibrated within our tolerances) TIRRON Reference is<br />calibrated at ISO 17025 certified laboratory with 1 year calibration interval. With 5<br />calibration points: 0, 20, 40, 60, 80 and 100<br />% FS. Available ranges 20 nmlpm - 8000<br />nlpm.<br />Tolerance and Uncertainty:<br />20nmlpm - 1000 nlpm:<br />-Tolerance: 1 % Measurement + 0.2 % Full<br />Scale of DUT<br />-Uncertainty: 0.5 % Measurement + 0.1%<br />Full Scale of used References</p>